479 East 186th Street Bronx, N.Y.  10458

Monday - Friday 7am-5pm 


Price: $180.00

    Quantity:
    Item #: S8910U3000
    Availability: In stock
    In stock Quantity: 2

    Overview

    Universal hot surface ignition module replaces multiple field installed hot surface ignition modules supplied by Honeywell, White-Rodgers, Robertshaw and Johnson. Uses a 120 VAC igniter. Includes cross reference, instructions, and accessories for easy replacement.

    Features

    • Replaces over 800 White-Rodgers, Robertshaw and Honeywell hot surface ignition models.
    • For 120 Vac (up to 5.0A) surface igniter (Norton 201/271 or equivalent).
    • S8910U 3000 Series has LED status indicator and microammeter ports for easy trouble shooting
    • For local (single rod) or remote (dual rod) rectification type flame sensing.
    • Contains easy-to-use cross reference and instructions plus the accessories required to replace the existing hot surface ignition module.
    • Provides one or three ignition trials (four-second or seven-second trials) per call for heat.
    • Field selectable number of ignition trials and trial time based on unit being replaced.
    • Igniter warm up time: 7 (12 seconds second and third trial), 17 (27 seconds second and third trial), 34, or 45 seconds

    Product Specifications

    Dimensions (in.)
    5 1/4 in. high x 4 1/16 in. wide x 1 15/16 in. deep
    Dimensions (mm)
    133 mm high x 103 mm wide x 49 mm deep
    Electrical Ratings
    24 Vac
    Frequency
    50 Hz; 60 Hz
    Approvals, Canadian Standards Association
    Design Certified
    Tradeline Value
    Tradeline
    Flame Failure Response Time (sec)
    1.5 sec.
    PrePurge
    32 seconds
    Ambient Temperature Range (F)
    -40 F to +175 F
    Ambient Temperature Range (C)
    -40 C to +79 C
    Ignition System Type
    Direct Hot Surface Ignition
    Ignition Sequence
    The number of trials for ignition and trial time is determined by the dip switch selection.
    Typical Gas Control
    VR8205, VR8305
    Type of Gas
    Natural or LP
    Flame Sense
    Single Rod or Two Rods
    Ignition Source
    Line Voltage (120 VAC) Hot Surface Element (Norton Model 201 or 270)
    Ignition Trials To Lockout
    1 or 3
    Lockout Timing
    4 sec. or 7 sec.
    Ignition Trial Time (sec)
    4 sec. or 7 sec.
    Maximum Valve Load @ 24 Vac (Amps)
    2A
    Typical Ignition Hardware
    Norton 201, Norton 271, Q354
    Between Trial Time (sec)
    (2) 96 sec (32 Seconds Prepurge and 64 seconds interpurge)