Overview
The SmartValve® System Controls combine gas flow control and electronic direct main burner ignition sequencing functions into a single unit. The ignition source is 120V hot surface igniter lighting the main burner flame. Provides all gas ignition safety functions by controlling gas flow, ignition source, and a 120 Vac combustion air blower. The control also monitors the appliance airflow proving switch circuit and limit string to assure proper appliance operation. The SmartValve System Controls provide prepurge, postpurge and timed trial for ignition with multiple ignition trials and auto reset from lockout. Diagnostic LED indicates system status.
Features
- The control communicates directly with the ST9160 Electronic Fan Timer (EFT) in typical forced warm air furnace applications.
- It can directly interface with the appropriate power supplies and a system thermostat for additional appliance applications.
- When controlled directly by a thermostat, the control does not provide a postpurge function, as power to the control is removed when the thermostat call for heat ends.
- This system is suitable for a wide range of fan-assisted combustion, gas-fired appliances including furnaces, rooftop furnaces, boilers, unit heaters, infrared heaters, water heaters and commercial cooking appliances.
Product Specifications
Dimensions (in.)3.2 in. wide x 4.9 in. high x 4.1 in.longDimensions (mm)81 mm wide x124 mm high x 104 mm long.IncludesLP Conversion KitItem TypeProductMounting0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.Electrical Ratings24 VacFrequency50 Hz; 60 HzApprovals, Canadian Standards AssociationCSA International: 112395Tradeline ValueUniversalFlame Failure Response Time (sec)2 sec @ 5 µAPrePurge15 secondsAmbient Temperature Range (F)0 F to 175 FAmbient Temperature Range (C)-18 C to +79 CIgnition System TypeDirect Hot Surface IgnitionIgnition Sequence7/12 secType of GasNatural (LP with included conversion kit)Flame SenseHSIIgnition SourceHSIIgnition Trials To Lockout4 trialsIgnition Trial Time (sec)7 secTypical Ignition HardwareNorton 601Body PatternStraight-throughOpening CharacteristicsFast-SlowPressure Regulator Setting (psi)3.5 in. WCPressure Regulator Setting (kPa)0.87 kPaPressure Ratings (psi)1/2 psiPressure Ratings (kPa)3.5 kPaInlet/Outlet Size (in.)1/2 in. NPT x 1/2 in. NPTPilot Gas OutletNoCapacity (ft³/hr)Maximum at 1 in. P.D.--150 ft³/hr; Maximum--200 ft³/hr; Minimum--20 ft³/hrCapacity (m³/hr)Maximum at 1 in. P.D.--4.2 m³/hr; Maximum--5.7 m³/hr; Minimum--0.6 m³/hrPressure Tapping1/8 in. - NPT