Products 121-132 of 278
Show
Availability: Out of Stock
Item #: Q3450C1185 -
Overview These SmartValve® System pilot burners provide pilot flame ignition and sensing for SmartValve Systems. They consist of a bracket, pilot target, ground electrode, replaceable igniter-flame rod, orifice assembly, compression fitting and spring clip. Features Used with SmartValve™ Systems.Replaceable Igniter-Flame Rod Assembly (Q3400A).Integral keyed plug provides quick, convenient connection of igniter and sensor to SmartValve™.Q3450 has front or 20 degree right, left flame...
Availability: Out of Stock
Item #: Q3450C2092 -
These SmartValve® System pilot burners provide pilot flame ignition and sensing for SmartValve Systems. They consist of a bracket, pilot target, ground electrode, replaceable igniter-flame rod, orifice assembly, compression fitting and spring clip. Features Used with SmartValve™ Systems.Replaceable Igniter-Flame Rod Assembly (Q3400A).Integral keyed plug provides quick, convenient connection of igniter and sensor to SmartValve™.Q3450 has front or 20 degree right, left flame patterns.Natural and...
Availability: In stock
Item #: Q345A1305 -
Intermittent Pilot Burner - Natural gas with BCR-18 orifice. Front tip A or B bracket.Non primary-aerated combination pilot burner and ignitor. Used with the S86, S860, S8610, or S8670 in intermittent pilot systems.FeaturesIncludes pilot burner with bracket, ceramic-insulated Kanthal flame rod/spark igniter and ground strap.Single tip style.Product SpecificationsApplicationPilot Burner for Intermittent Pilot ApplicationsIncludesSpecial mounting bracket with screws to convert "B" bracket to "A"...
Availability: In stock
Item #: Q345A1313 -
Intermittent Pilot Burner -Left Target- Natural gas with BCR-18 orifice. Front tip A or B bracket.OverviewNon primary-aerated combination pilot burner and ignitor. Used with the S86, S860, S8610, or S8670 in intermittent pilot systems. FeaturesIncludes pilot burner with bracket, ceramic-insulated Kanthal flame rod/spark igniter and ground strap.Single tip style. Product SpecificationsApplicationPilot Burner for Intermittent Pilot ApplicationsIncludesSpecial mounting bracket with screws to...
Availability: In stock
Item #: Q345A1321 -
Electronic Pilot Burner - (Right Target) - nat gas w. BCR-18 orifice.OverviewNon primary-aerated combination pilot burner and ignitor. Used with the S86, S860, S8610, or S8670 in intermittent pilot systems. FeaturesIncludes pilot burner with bracket, ceramic-insulated Kanthal flame rod/spark igniter and ground strap.Single tip style. Product SpecificationsApplicationPilot Burner for Intermittent Pilot ApplicationsIncludesSpecial mounting bracket with screws to convert "B" bracket to "A"...
Availability: Out of Stock
Item #: Q345U1005 -
Non primary-aerated combination pilot burner and ignitor. Used with the S86, S860, S8610, or S8670 in intermittent pilot systems. Features Includes pilot burner with bracket, ceramic-insulated Kanthal flame rod/spark igniter and ground strap.Single tip style.
Availability: In stock
Item #: Q348U1009 -
These pilot burner/igniter-sensors provide pilot flame ignition and sensing in intermittent pilot systems. They consist of a bat-wing type pilot burner with a combination spark igniter and flame sensor. Features Includes pilot burner with bracket, ceramic-insulated Kanthal flame rod/spark igniter and ground strap.Bat-wing tip style.
Availability: In stock
Item #: R7284U1004 -
Honeywell Universal electronic oil primary with programmable parameters and LCD display. The R7284 oil primary is a digital, universal primary control, engineered to address the most common industry needs. The R7284U parameters are user defined and provides detailed actionable diagnostics. Features A single part number for nearly all applications helps reduce inventory cost16 character two line tri-lingual display provides simple programming and diagnostics on select modelsEnunciation of...
Availability: In stock
Item #: R7847A1033 -
Solid state plug-in amplifiers that respond to flame detector inputs to indicate the presence of flame when used with 7800 SERIES relay modules.FeaturesFlame failure response time of 0.8 or 3.0 seconds.Flame signal strength ranges from 0.0 to 5.0 Vdc.Plug into 7800 relay module through printed circuit board edge connector keyed for proper orientation.Flame signal test jacks to measure amplifier flame signal voltage.Color-coded labels identify flame detection type. Dynamic Self-Check Amplifier...
Availability: In stock
Item #: R7848A1008 -
viewSolid state plug-in amplifiers that respond to flame detector inputs to indicate the presence of flame when used with 7800 SERIES relay modules.FeaturesFlame failure response time of 0.8 or 3.0 seconds.Flame signal strength ranges from 0.0 to 5.0 Vdc.Plug into 7800 relay module through printed circuit board edge connector keyed for proper orientation.Flame signal test jacks to measure amplifier flame signal voltage.Color-coded labels identify flame detection type. Dynamic Self-Check...
Availability: Out of Stock
Item #: R7849A1015 -
Availability: In stock
Item #: R7849A1023 -
OverviewSolid state plug-in amplifiers that respond to flame detector inputs to indicate the presence of flame when used with 7800 SERIES relay modules. FeaturesFlame failure response time of 0.8 or 3.0 seconds.Flame signal strength ranges from 0.0 to 5.0 Vdc.Plug into 7800 relay module through printed circuit board edge connector keyed for proper orientation.Flame signal test jacks to measure amplifier flame signal voltage.Color-coded labels identify flame detection type. Dynamic Self-Check...