    Honeywell Aquastat Relay, 180 – 240 F range with 15 degree F fixed differential, low(24v) volt.

    Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors.

    Features

    • High limit opens burner circuit only.
    • Select models include transformer and accessory terminals for adding a remote low limit controller.
    • Case available for horizontal or vertical mounting.
    • Requires a 24 Vac thermostat with heat anticipator set at 0.2A.
    • TRADELINE models include well adapter, tube of heat conductive compound and range stops..


    Product Specifications

    Hazmat InformationUN1294 TolueneApplicationHigh LimitDimensions (in.)6 1/8 in. high x 4 5/16 in. wide x 3 1/8 in. deepDimensions (mm)156 mm high x 110 mm wide x 79 mm deepMaximum Safe Operating Pressure (psi)Immersion Well: 255 psiMaximum Safe Operating Pressure (kPa)Immersion Well: 1757 kPaTemperature Range (F)Maximum--150 F with 1.2 A 24 V load; 77 F with 1.4 A 24 V loadTemperature Range (C)Maximum--66 C with 1.2 A 24 V load; 25 C with 1.4 A 24 V loadIncludesMolex® plug for use with vent damper, includes heat-conductive compound.; Molex(r) plug for use with vent damper, includes heat-conductive compound.MountingVertical MountElectrical RatingsLow Voltage: 0.8 A max. @ 24 Vac; 0.25 A @ 0.25 to 12 Vdc; At Locked Rotor-- 44.4A @ 120 Vac: 22.2A @ 240 VacFrequency60 HzApprovals, Underwriters Laboratories Inc.UL Listed: File No. MP466, Vol. 13, Sec. 2, Guide No. MBPR2.Approvals, CSACertified: File No. LR95329-1Tradeline ValueTradelineElectrical ConnectionsQuick-Connect / ScrewOperating Humidity Range (% RH)0 to 95% RH, non-condensingVoltage120 VacOperating Temperature Range (F)High Limit-- 180 F to 240 FOperating Temperature Range (C)High Limit-- 82 C to 116 CDifferential Temperature (F)15 F fixedSwitching ActionSPST: High Limit & CirculatorAnticipator Setting0.2 ACapillary Length (in.)4 1/2 in.Insulation Depth (in.)1 1/2 in. to 3 in. less wellInsulation Depth (mm)38 mm to 76 mm less wellCapillary Length (mm)114 mmElectrical Ratings, BurnerAt Full Load-- Low Voltage: 0.8 A max. @ 24 Vac: Line Voltage: 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor-- Line Voltage: 44.4 A @ 120 Vac: 22.7 A @ 240 Vac; Millivolt--0.25 A @ 1/4 to 12 VdcElectrical Ratings, CirculatorAt Full Load-- 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor-- 44.4 A @ 120 Vac: 22.2 A @ 240 Vac