50M56U-843 UNIVERSAL INTEGRATED
HSI FURNACE CONTROL KIT
Replaces Virtually All White-Rodgers and Competitive Single Stage
Carbide and Nitride HSI Systems with 80V or 120V Ignitors.
Replaces More Models than Honeywell S9200U1000
FEATURES
• 3 Fan Speeds – cool, low heat & high heat speeds.
• Universal HotRod nitride ignitor kit – 21D64-2.
• 9 quick-select/quick-connect wiring harnesses.
• Red LED diagnostic flash codes with stored fault recall.
• Low voltage fuse protection, 3A replaceable automotive type.
• Humidifier & Electronic Air Cleaner connections (optional).
SPECIFICATIONS
Electrical Rating:
Input Voltage . . . . . . . . . . . . . . . . . . . . 25 VAC 50/60 Hz
Max. Input Current . . . . . . . . . . . . . . . . 25 VAC: 0.45 amp
Gas Valve Relays . . . . . . . . . . . . . . . . 1.5 amp @ 25 VAC 50/60 Hz
Inducer Relay . . . . . . . . . . . . . . . . . . . 2.2 FLA–3.5 LRA @ 120 VAC
Circulator Relay . . . . . . . . . . . . . . . . . . 14.5 FLA–25.0 LRA @ 120 VAC
Ignitor Relay . . . . . . . . . . . . . . . . . . . . 6.0 amp @ 120 VAC 50/60 Hz (resistive)
Flame Current Requirements:
Minimum current to insure flame detection 1 μa DC*
Maximum current for non-detection . . . 0.1 μa DC*
Maximum allowable leakage resistance 100 M ohms
*Measured with a DC microameter in the flame probe lead
Operating Temperature Range . . . . . . -40° to 176°F (-40° to 80°C)
Flame Failure Response Time . . . . . . 2.0 sec
PARTS AND ACCESSORIES See end of this section for parts and accessories
TECHNICAL HELP
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . See pages 190–192
UNIVERSAL
REPLACEMENT
INTEGRATED
HSI FURNACE CONTROL
Model
Number Pre-Purge
Ignitor
Warm-Up Retries
Heat
Delay to
Fan ON
Heat Delay
to Fan OFF
Cool
Delay to
Fan ON
Cool
Delay to
Fan OFF
Automatic
Reset
Time
50M56U-843 30 17 2 30 100/150 6 45 60 minutes
PAGES
?
190–192
50M56U-843
Includes:
• Module
• Wiring Harness
• HotRod
Ignitor Kit
Consult online Cross Reference for other suggested replacements for this item.
Cross Reference