Item #: VR8300A3500 -
Combination gas control for use in 24 Vac gas-fired, standing pilot appliances with capacities from 30 to 300 cfh. Features Control includes safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment.Compact size.Provides two automatic valves.Solenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat ends.Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is...
Availability: Out of Stock
Item #: VR8300H4501 -
Single Stage, 24 Vac, Slow Opening, Standing Pilot Gas Valve. 3/4 x 3/4". Set 3.5" WC Gas valve for use in 24 Vac, gas-fired, standing pilot appliances with capacities from 30 to 300 cfh. Features Gas valves include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment. Compact size. Provide two automatic valves. Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm-operated second automatic...
Availability: Out of Stock
Item #: VR8200H2151 -
Gas valves for use in 24 Vac, gas-fired, standing pilot appliances with capacities from 20 to 200 cfh. Features Gas valves include manual valve, two automatic operators, servo pressure regulator and pilot adjustment.Compact size.Provide two automatic valves.Solenoid-operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.Meet codes...
Availability: Out of Stock
Item #: VR8200C1041 -
Gas valves for use in 24 Vac, gas-fired, standing pilot appliances with capacities from 2to 200 cfh. Features Gas valves include manual valve, two automatic operators, servo pressure regulator and pilot adjustment.Compact size.Provide two automatic valves.Solenoid-operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.Meet codes...
Availability: In stock
Item #: VR8204A2076 -
Gas valves for use in 24 Vac, gas-fired, intermittent pilot appliances with capacities from 20 to 200 cfh. Features Gas valves include manual valve, two automatic operators, servo pressure regulator and pilot adjustment.Use with S86F,H; S8600F,H and S8610 Control Modules.Compact size.Provide two automatic valves.Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.Diaphragm operated second automatic valve opens under control of regulator;...
Availability: In stock
Item #: VR8304M4507 -
Honeywell 3/4" x 1/2" or 3/4" Electronic Standard Open Gas Valve.Gas valve for use in 24 Vac, gas-fired, intermittent pilot appliances with capacities from 30 to 415 cfh.FeaturesGas valves include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment.Use with S86F,H; S860D; S8600F,H; S8610 and S90A,B Control Modules.Compact size.Provide two automatic valves.Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for...
Availability: In stock
Item #: VR8204C1019 -
Gas valves for use in 24 Vac, gas-fired, intermittent pilot appliances with capacities from 20 to 200 cfh. FeaturesGas valves include manual valve, two automatic operators, servo pressure regulator and pilot adjustment.Use with S86F,H; S8600F,H and S8610 Control Modules.Compact size.Provide two automatic valves.Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.Diaphragm operated second automatic valve opens under control of regulator;...
Availability: Out of Stock
Item #: VR8304P4504 -
Single Stage, 24 Vac, Step Opening Intermittent Pilot 3/4 x 3/4 Step rate 0.9" WC, Full Rate 3.5" WC Gas valve for use in 24 Vac, gas-fired, intermittent pilot appliances with capacities from 30 to 415 cfh.
Availability: In stock
Item #: VR8204H1147 -
Gas valves for use in 24 Vac, gas-fired, intermittent pilot appliances with capacities from 20 to 200 cfh. Features Gas valves include manual valve, two automatic operators, servo pressure regulator and pilot adjustment.Use with S86F,H; S8600F,H and S8610 Control Modules.Compact size.Provide two automatic valves.Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.Diaphragm operated second automatic valve opens under control of regulator;...
Availability: Out of Stock
Item #: VR8304H4503 -
Gas valves for use in 24 Vac, gas-fired, intermittent pilot appliances with capacities from 30 to 415 cfh. Features Gas valves include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment.Use with S86F,H; S860D; S8600F,H; S8610 and S90A,B Control Modules.Compact size.Provide two automatic valves.Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.Diaphragm-operated second automatic valve opens under...
Availability: Out of Stock
Item #: RM7895A1014 -
Microprocessor-based integrated primary burner control for automatically fired gas, oil, or combination fuel single burner applications. Provides level of safety, functional capability and features beyond conventional controls. FeaturesFunctions include automatic burner sequencing, flame supervision, system status indication, system or self-diagnostics and troubleshooting.Subbase, amplifier, and prepurge timer are required for operation.Options include PC interface, keyboard display module,...
Availability: Out of Stock
Item #: RM7895A1048 -
Microprocessor-based integrated primary burner control for automatically fired gas, oil, or combination fuel single burner applications. Provides level of safety, functional capability and features beyond conventional controls. FeaturesFunctions include automatic burner sequencing, flame supervision, system status indication, system or self-diagnostics and troubleshooting.Subbase, amplifier, and prepurge timer are required for operation.Options include PC interface, keyboard display module,...